Series 50 Model 51


2-WAY NORMALLY OPEN Valve


Our original mini — engineered for space economy without sacrificing performance. Typical applications include medical, analytical instrumentation. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Tough with options to use in hazardous location environments or low watt applications.
  • High quality engineering.
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
CONDUIT HOUSING
ACDC 1/8 NPT PORTS1/8 NPT PORTS

4002001/32.02051G8XGM51G8XCM
2001003/64.04851H8XGM51H8XCM
125601/16.07551J8XGM51J8XCM
40403/32.15051K8XGM51K8XCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (51J8XGM 120/60) repair pack (K51JDX ac)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O51JDDGM 120/60)


Operating Conditions

Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 6.0 Watts, DC — 7.0 Watts
Coil Construction
Molded and potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 0.38 lb Conduit Valve: 0.44 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers, Low Wattage, Spade Terminal Coil and Explosion Proof

Series 50 General Purpose Valves Conduit


MODEL 51
2WNO CONDUIT CONNECTION
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing


MODEL 51 STUD MOUNT BODY
2WNO CONDUIT CONNECTION
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Series 50 General Purpose Valves Grommet


MODEL 51
2WNO GROMMET WITH LEADS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing


MODEL 51 STUD MOUNT BODY
2WNO
GROMMET WITH LEADS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Series 50 General Purpose Valves Yoke Leads


MODEL 51
2WNO
YOKE WITH LEADS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing


MODEL 51 STUD MOUNT BODY
2WNO
YOKE WITH LEADS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Series 50 General Purpose Valves Yoke Spades


MODEL 51
2WNO
YOKE WITH SPADE TERMINALS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing


MODEL 51 STUD MOUNT BODY
2WNO
YOKE WITH SPADE TERMINALS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Series 50 General Purpose Valves Grommet/Bracket Connection

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
MODEL 51
2WNO
GROMMET/BRACKET WITH LEADS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
MODEL 51 STUD MOUNT BODY
2WNO
GROMMET/BRACKET WITH LEADS
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Series 50 General Purpose Valves Conduit/Bracket Connection

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
MODEL 51
2WNO
CONDUIT/BRACKET CONNECTION
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
MODEL 51 STUD MOUNT BODY
2WNO
CONDUIT/BRACKET CONNECTION
Download Drawings IGS SolidWorks SLDPRT STEP Parasolid DXF Adobe PDF 2D Drawing

--> 

 

Series 50 OPERATORS CONDUIT


MODEL 51 1/8-27
2WNO CONDUIT CONNECTIONDownload Drawings DXF IGS Adobe PDF 2D Drawing SolidWorks SLDASM SolidWorks SLDDRW SolidWorks SLDPRT STEP Parasolid

Series 50 OPERATORS GROMMET


MODEL 51 1/8-27
2WNO GROMMET WITH LEADSDownload Drawings DXF IGS Adobe PDF 2D Drawing SolidWorks SLDASM SolidWorks SLDDRW SolidWorks SLDPRT STEP Parasolid

Series 50 OPERATORS YOKE LEADS


MODEL 51 1/8-27
2WNO MOLDED COIL WITH YOKEDownload Drawings DXF IGS Adobe PDF 2D Drawing SolidWorks SLDASM SolidWorks SLDDRW SolidWorks SLDPRT STEP Parasolid

Series 50 OPERATORS YOKE SPADE


MODEL 51  1/8-27
2WNO SPADE COIL WITH YOKEDownload Drawings DXF IGS Adobe PDF 2D Drawing SolidWorks SLDASM SolidWorks SLDDRW SolidWorks SLDPRT STEP Parasolid

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1