3-WAY NORMALLY CLOSED (piped) Valve
General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants, and many other media by the use of different seals. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
- General purpose valve with reduced power consumption.
- Increased versatility.
- For pneumatic and hydraulic applications.
- Increased capability to handle hot air, water, and refrigerants.
- High quality engineering.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||||||
|---|---|---|---|---|---|---|---|---|---|
| GAS | LIQUID | ||||||||
| AC | DC | AC | DC | N.C. | N.O. | N.C. | N.O. | GROMMET 1/8" NPT | CONDUIT 1/8" NPT |
| 215 | 135 | 215 | 135 | 1/32 | 1/32 | .022 | .022 | LW53GG8XGM | LW53GG8XCM |
| 215 | 120 | 120 | 65 | 1/32 | 3/64 | .022 | .048 | LW53GH8XGM | LW53GH8XCM |
| 135 | 50 | 40 | 30 | 1/32 | 1/16 | .022 | .075 | LW53GJ8XGM | LW53GJ8XCM |
| 70 | 35 | 30 | 20 | 1/32 | 5/64 | .022 | .134 | LW53GV8XGM | LW53GV8XCM |
| 55 | 30 | 25 | 15 | 1/32 | 3/32 | .022 | .156 | LW53GK8XGM | LW53GK8XCM |
| 120 | 70 | 120 | 65 | 3/64 | 3/64 | .055 | .048 | LW53HH8XGM | LW53GN8XCM |
| 120 | 50 | 40 | 30 | 3/64 | 1/16 | .055 | .075 | LW53HJ8XGM | LW53GO8XCM |
| 70 | 35 | 30 | 20 | 3/64 | 5/64 | .055 | .134 | LW53HV8XGM | LW53HV8XCM |
| 55 | 30 | 25 | 15 | 3/64 | 3/32 | .055 | .156 | LW53HK8XGM | LW53HK8XCM |
| 85 | 40 | 40 | 30 | 1/16 | 1/16 | .075 | .075 | LW53JJ8XGM | LW53JJ8XCM |
| 70 | 35 | 30 | 20 | 1/16 | 5/64 | .075 | .134 | LW53JV8XGM | LW53JV8XCM |
| 55 | 30 | 25 | 15 | 1/16 | 3/32 | .075 | .156 | LW53JK8XGM | LW53JK8XCM |
| 50 | 30 | 30 | 20 | 5/64 | 5/64 | .134 | .134 | LW53VV8XGM | LW53VV8XCM |
| 50 | 30 | 25 | 15 | 5/64 | 3/32 | .134 | .156 | LW53VK8XGM | LW53VK8XCM |
| 35 | 20 | 25 | 15 | 3/32 | 3/32 | .150 | .156 | LW53KK8XGM | LW53KK8XCM |
Operating Conditions
- Media
- Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
- Valve Temperature Range
- Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
- Maximum Operating Pressure Differentials
- See table above.
- Burst Pressure
- 5000 PSI
- Leakage
- Bubble tight for standard valves.
- Vacuum
- To 5 Microns*
Electrical Characteristics
- Coil Voltage
- 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
- Nominal Power
- AC — 2.5 Watts DC — 2.5 Watts
- Coil Construction
- Non-molded Class A, Molded and potted Class F. (Class H optional)
- Typical Response Time on Air
- 4 - 16 Milliseconds
- Operating Speed
- Up to 600 CPM
- Duty Cycle
- Continuous
Mechanical Characteristics
- Internal Components
- Stainless Steel. Copper – AC Only.
- Elastomers
- Nitrile (Buna) (Std.). Many other elastomers available.*
- Orifice Diameter
- See table above.
- Porting
- 1/8" NPT (Std.)
- Life Expectancy
- Millions of cycles, depending on application, lubrication, etc.
- Valve Weight
- Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
- Repair Packs
- See table above.
- Options
- Alternate Port Locations, Metering and Alternate Elastomers*
Series 50 LW Low Watt Valves Piped Conduit Connection
3WNC PIPED EXHAUST
CONDUIT CONNECTION
10-32 PORTS
3WNC PIPED EXHAUST
CONDUIT CONNECTION
OPTION "E"
3WNC PIPED EXHAUST
CONDUIT CONNECTION
OPTION "O"
3WNC PIPED EXHAUST
CONDUIT CONNECTION
BODY OPTION "R"
3WNC PIPED EXHAUST
CONDUIT CONNECTION
METERED BODY
3WNC PIPED EXHAUST
CONDUIT CONNECTION
Series 50 LW Low Watt Valves Piped Conduit/Bracket Connection
PIPED EXHAUST
3WNC
CONDUIT/BRACKET CONNECTION
10-32 PORTS
3WNC PIPED EXHAUST
CONDUIT/BRACKET CONNECTION
BODY OPTION "E"
3WNC PIPED EXHAUST
CONDUIT/BRACKET CONNECTION
BODY OPTION "O"
3WNC PIPED EXHAUST
CONDUIT/BRACKET CONNECTION
BODY OPTION "R"
3WNC PIPED EXHAUST
CONDUIT/BRACKET CONNECTION
METERED BODY
3WNC PIPED EXHAUST
CONDUIT/BRACKET CONNECTION
Series 50 LW Low Watt Valves Piped Grommet Connection
3WNC PIPED EXHAUST
GROMMET WITH LEADS
10-32 PORTS
3WNC PIPED EXHAUST
GROMMET WITH LEADS
BODY OPTION "E"
3WNC PIPED EXHAUST
GROMMET WITH LEADS
BODY OPTION "O"
3WNC PIPED EXHAUST
GROMMET WITH LEADS
BODY OPTION "R"
3WNC PIPED EXHAUST
GROMMET WITH LEADS
METERED BODY
3WNC PIPED EXHAUST
GROMMET WITH LEADS
Series 50 LW Low Watt Valves Piped Grommet/Bracket Connection
3WNC
PIPED EXHAUST
GROMMET/BRACKET WITH LEADS
10-32 PORTS
3WNC PIPED EXHAUST
GROMMET/BRACKET WITH LEADS
BODY OPTION "E"
3WNC PIPED EXHAUST
GROMMET/BRACKET WITH LEADS
BODY OPTION "O"
3WNC PIPED EXHAUST
GROMMET/BRACKET WITH LEADS
BODY OPTION "R"
3WNC PIPED EXHAUST
GROMMET/BRACKET WITH LEADS
METERED BODY
3WNC PIPED EXHAUST
GROMMET/BRACKET WITH LEADS
Series 50 LW Low Watt Valves Piped Yoke Leads
3WNC
PIPED EXHAUST
YOKE WITH LEADS
10-32 PORTS
3WNC PIPED EXHAUST
YOKE WITH LEADS
BODY OPTION "E"
3WNC PIPED EXHAUST
YOKE WITH LEADS
BODY OPTION "O"
3WNC PIPED EXHAUST
YOKE WITH LEADS
BODY OPTION "R"
3WNC PIPED EXHAUST
YOKE WITH LEADS
METERED BODY
3WNC PIPED EXHAUST
YOKE WITH LEADS
Series 50 LW Low Watt Valves Piped Yoke Spades
3WNC
PIPED EXHAUST
YOKE WITH SPADE TERMINALS
10-32 PORTS
3WNC PIPED EXHAUST
YOKE WITH SPADE TERMINALS
BODY OPTION "E"
3WNC PIPED EXHAUST
YOKE WITH SPADE TERMINALS
BODY OPTION "O"
3WNC PIPED EXHAUST
YOKE WITH SPADE TERMINALS
BODY OPTION "R"
3WNC PIPED EXHAUST
YOKE WITH SPADE TERMINALS
METERED BODY
3WNC PIPED EXHAUST
YOKE WITH SPADE TERMINALS

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.
The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.
Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.