Series 50 ELW Model ELW53


3-WAY NORMALLY CLOSED (piped) Valve


A UL and CSA listed, low watt, miniature hazardous location valve with minimal space and energy requirements in volatile environments. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.

  • Smallest hazardous location solenoid valve.
  • Best ambient and high temperature ratings on the market.
  • NEMA 4 rating is standard with encapsulated coil.
  • High quality engineering.
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTOR  VALVE NUMBER
 
GASLIQUID    
ACDCACDCN.C.N.O.N.C.N.O.   

2151352151351/321/32.022.020  ELW53GG8XCCP
215120120651/323/64.022.048  ELW53GH8XCCP
1355040301/321/16.022.075  ELW53GJ8XCCP
703530201/321/16.022.134  ELW53GV8XCCP
553025151/323/32.022.150  ELW53GK8XCCP
12070120653/643/64.055.048  ELW53HH8XCCP
1205040303/641/16.055.075  ELW53HJ8XCCP
703530203/641/16.055.134  ELW53HV8XCCP
553025153/643/32.055.150  ELW53HK8xCCP
854040301/161/16.075.075  ELW53JJ8xCCP
703530201/161/16.075.134  ELW53JV8XCCP
553025151/163/32.075.150  ELW53JK8XCCP
503030205/641/16.134.134  ELW53VV8XCCP
503025155/643/32.134.150  ELW53VK8XCCP
352025155/643/32.156.150  ELW53KK8XCCP

Operating Conditions

Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts DC — 1.8 Watts
Coil Construction
Encapsulated Class F Coil with third wire ground
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Encapsulated with 1/2 NPT conduit
Listings
Valves are UL listed for Hazardous Locations — Class I, Div 1, Groups A, B, C, and D – Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G. “T” Rating as low as T5.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.60 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*

Series 50 ELW Encapsulated Low Watt Valves


MODEL ELW53
3WNC PIPED EXHAUST
EXPLOSION PROOF


MODEL ELW53 10-32 PORTS
3WNC PIPED EXHAUST
EXPLOSION PROOF


MODEL ELW53 BODY OPTION "E"
3WNC PIPED EXHAUST
EXPLOSION PROOF


MODEL ELW53 BODY OPTION "O"
3WNC PIPED EXHAUST
EXPLOSION PROOF


MODEL ELW53 BODY OPTION "R"
3WNC PIPED EXHAUST
EXPLOSION PROOF


MODEL ELW53 METERED BODY
3WNC PIPED EXHAUST
EXPLOSION PROOF

 
Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1