Series 20 Model EL24


3-WAY NORMALLY OPEN Valve


PeterPaul explosion proof solenoid valves are used where fire or explosion hazards exist due to the presence of flammable gas or vapors, flammable liquids, combustible dust or easily ignitable fibers. The low watt feature assures low power consumption, reducing drain on electrical systems. This is a benefit for renewable energy applications and where the solenoid valve must be on continuously.

  • Heavy duty and made of stainless steel.
  • A real workhorse with proven performance.
  • Low power consumption best for renewable energy and limited resource applications.
  • Wide range of orifice sizes from 1/32″ to 1/8″.
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
DCINEXHINEXH1/8 NPT PORTS1/4 NPT PORTS

4001/321/32.024.024EL24GG7XCCP-∆EL24GG9ZCCP-∆
1503/643/64.052.052EL24HH7XCCP-∆EL24HH9ZCCP-∆
401/161/16.095.095EL24JJ7XCCP-∆EL24JJ9ZCCP-∆
253/323/32.156.156EL24KK7XCCP-∆EL24KK9ZCCP-∆

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (EL24GG7XCCP-N 24/DC) repair pack (2KEL24GG-N DC)

When ordering operators add the letter “O” to the front of the valve number, and the body code will change. Contact the factory for the complete part number.


Operating Conditions

Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
-22°F(-30°C) to 140°F (60°C) Exception: FKM is -4°F (-20°C) to 140°F (60°C).
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12, 24/DC
Nominal Power
1.8 Watts
Coil Construction
Potted Class F coil with 36” black lead wires and 36” green ground wire.
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel
Elastomers
Buna, Fluorocarbon (FKM), Low Temperature Buna, EPDM or Neoprene.
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are cULus listed for Hazardous Locations. — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2 Groups A, B, C, D, E, F, and G.
Certification
North American IECEx/ATEX
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.38 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Manual Override, Alternate Elastomers*

Series 20 HAZARDOUS LOCATION VALVES

MODEL EL24 3WNO 
1/4-18 NPT EXPLOSION PROOF

MODEL EL24 3WNO 
1/8-27 NPT EXPLOSION PROOF

MODEL EL24 3WNO 
BODY OPTION "O" EXPLOSION PROOF

MODEL EL24 3WNO 
MANUAL OVERRIDE EXPLOSION PROOF

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com

MODEL EL24 3WNO 
METERING EXPLOSION PROOF

 
Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1


GP-1119 ATEX IECEx UKEx Signed Declaration of Conformity page 1 GP-1119 ATEX IECEx UKEx Signed Declaration of Conformity page 2