SERIES 20 MODEL MLV26 (REVERSE POLARITY)


3-WAY MULTI-PURPOSE Valve


3-Way Multi-Purpose Fixed Polarity Magnet Latching Valve - This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.

  • Valve is magnetic latching.
  • Meets today's demand for economy of space.
  • Uses power only during latching and un-latching.
  • Great for medical and chemical analyzers.
  1. Common Black wire set to Neutral (-)
    1. Pulse Yellow lead to Positive (+) to latch
    2. Pulse Blue lead to Positive (+) to un-latch
  2. Common Black wire set to Positive (+)
    1. Pulse Yellow lead to Neutral (-) to un-latch
    2. Pulse Blue lead to Neutral (-) to latch

3 WIRE COIL

2WIRE

DIN COIL (3 TERMINALS WITH GROUND)

3PIN

VALVE SPECIFICATION

MAX. OPER. VALVE NUMBER
PRESS. DIFF.ORFICE SIZECV FACTOR DIN COIL (3 TERMINALS WITH GROUND)3 WIRE COIL
DCN.C.N.O.N.C.N.O. 1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS

4001/321/32.024.024 26GG7XELM26GG9ZELM26GG7XGLM26GG9ZGLM
1503/643/64.052.052 26HH7XELM26HH9ZELM26HH7XGLM26HH9ZGLM
1001/161/16.095.095 26JJ7XELM26JJ9ZELM26JJ7XGLM26JJ9ZGLM
753/323/32.156.156 26KK7XELM26KK9ZELM26KK7XGLM26KK9ZGLM

Operating Conditions

Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
6, 9, 12, 24/DC
Nominal Power
DC — 10.0 Watts
Coil Construction
Molded Class B with DIN 43650 Form A Connector (Std.), Leadwires (Opt.) For your convenience we have the female DIN style mating connector No. 20-198** available for an additional fee.*
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM

Mechanical Characteristics

Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8” and 1/4” NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.

Series 20 Model 26 Magnetic Latching


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL


3-WAY MULTI-PURPOSE MAGNETIC LATCHING COIL

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1