SERIES 80 MODEL MLV828 (REVERSE POLARITY)


2-WAY NORMALLY CLOSED Valve


2-Way Large Orifice, Internally Piloted, Reverse Polarity Magnet Latching Valve - PeterPaul offers a line of large orifice solenoid valves to address process industry requirements for high flow rate or quick dump and fill capacity. These DC powered valves are also suited for gas and liquid applications. Port sizes for pilot lift, two-way normally closed versions range from 1/2” to 3” NPT, with pressure ratings from 3 to 200 PSI.

  • Large orifice sizes for high flow applications.
  • Body is made of brass forgings or 316 stainless steel.
  • Operates on differential pressure — internal pilot.
  • NPT threaded connections.
  • Same coils and housings as our popular 20 Series.
Neutral (−)
  1. Pulse Yellow lead to Positive (+) to latch
  2. Pulse Blue lead to Positive (+) to un-latch
Positive (+)
  1. Pulse Yellow lead to Neutral (−) to un-latch
  2. Pulse Blue lead to Neutral (−) to latch

2 WIRE COIL

2 Wire Flying Leads Latching Diagram

DIN COIL (2 TERMINALS WITH GROUND)

2 Wire DIN Latching Diagram

VALVE SPECIFICATIONS

MAX. OPER. PRESS. DIFF.MIN. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORPIPE SIZEVALVE NUMBER
DC     
2 WIRE COILDIN COIL

20031/24.01/2 NPT828B12DGLM828B12DELM
20033/45.83/4 NPT828Y19DGLM828Y19DELM
2003113.01 NPT828D13DGLM828D13DELM
20031 1/229.01 1/2 NPT828E14DGLM828E14DELM
2003246.02 NPT828F16DGLM828F16DELM
2003376.02 1/2 NPT828W17DGLM828W17DELM
2003398.03 NPT828W18DGLM828W18DELM

 

Operating Conditions

Media
Air, water, and other fluids compatible with Buna seals. Hot water, steam, gasoline and many oils require special seal materials. Consult representative or factory.(Series 80 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Leakage
Bubble tight

Electrical Characteristics

Coil Voltage
6, 9, 12, 24/DC
Nominal Power
DC — 10 Watts
Coil Construction
Molded
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 100 CPM

Mechanical Characteristics

Internal Components
Stainless Steel (Std.)
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
 

SERIES 80 MODEL MLV828 2WNC MAGNET LATCHING DIN COIL


2WNC MAGNET LATCHING DIN COIL 1-1/2" NPT PORTS


2WNC MAGNET LATCHING DIN COIL 1/2" NPT PORTS


2WNC MAGNET LATCHING DIN COIL 1" NPT PORTS


2WNC MAGNET LATCHING DIN COIL 2-1/2" NPT PORTS


2WNC MAGNET LATCHING DIN COIL 2"NPT PORTS


2WNC MAGNET LATCHING DIN COIL 3/4" NPT PORTS


2WNC MAGNET LATCHING DIN COIL 3" NPT PORTS

 

SERIES 80 MODEL 828 2WNC MAGNET LATCHING COIL WITH LEADS


2WNC MAGNET LATCHING COIL WITH LEADS 1-1/2" NPT PORTS


2WNC MAGNET LATCHING COIL WITH LEADS 1/2" NPT PORTS


2WNC MAGNET LATCHING COIL WITH LEADS 1" NPT PORTS


2WNC MAGNET LATCHING COIL WITH LEADS 2-1/2" NPT PORTS


2WNC MAGNET LATCHING DIN COIL 2"NPT PORTS


2WNC MAGNET LATCHING COIL WITH LEADS 3/4" NPT PORTS


2WNC MAGNET LATCHING COIL WITH LEADS 3" NPT PORTS

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1