Series 70 Model 74


3-WAY NORMALLY OPEN Valve


Super valves that have ratings that formerly required valves of much greater size. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Largest direct acting (non-piloted) valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
CONDUIT HOUSING
ACDCINLETEXH.INLETEXH.1/4 NPT PORTS1/4 NPT PORTS

3503501/161/16.09.0974JJ9ZGM74JJ9ZCM
2502503/323/32.22.2274KK9ZGM74KK9ZCM
1751751/81/8.35.3574NN9ZGM74NN9ZCM
1251255/325/32.45.4574OO9ZGM74OO9ZCM
1001003/163/16.50.5074PP9ZGM74PP9ZCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (74PP9ZGM 120/60) repair pack (K74PPX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O74PPDDGM 120/60)


Operating Conditions

Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Molded Class F (Std.), Potted and Class H Option
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 2.00 lb Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers

Series 70 3WNO DIN STYLE COIL

Model 74 1/4-18 NPT 3WNO DIN Style Coil

MODEL 74
1/4-18 NPT 3WNO DIN STYLE COIL

Series 70 General Purpose Valves Conduit

Model 74 1/4-18 NPT 3WNO Conduit Connection

MODEL 74 1/4-18 NPT
3WNO
CONDUIT CONNECTION

Series 70 General Purpose Valves Grommet

Model 74 1/4-18 NPT 3WNO Grommet with Leads

MODEL 74 1/4-18 NPT
3WNO
GROMMET WITH LEADS

Series 70 General Purpose Valves Grommet/Bracket Connection

Model 75 1/4-18 NPT 3WNO Grommet/Bracket Connection 
MODEL 75 1/4-18 NPT
3WNO
GROMMET/BRACKET CONNECTION

Series 70 General Purpose Valves Conduit/Bracket Connection

Model 74 1/4-18 NPT 3WNO Conduit/Bracket Connection 
MODEL 74 1/4-18 NPT
3WNO
CONDUIT/BRACKET CONNECTION

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1