Series 20 Model H23


3-WAY NORMALLY CLOSED (e to a) Valve


PeterPaul’s model H23 has a dual operator valve that allows the same media control as a three-way normally closed valve but at much higher pressure ratings than previously available. To function as a 3-way normally closed valve, operators must be alternately energized and de-energized. Pressure applied to the “IN” port must always be equal to or greater than the pressure in the “CYL” port. Air and other non-corrosive gases, water, and oil.

  • Made for higher pressure ratings.
  • Precision stainless steel, free-floating plunger.
  • Kel-F pin sealing element.
  • Orifice guides the sealing pin for near-perfect alignment.
GAS PRESSURE RATINGSORIFICE SIZECV FACTORVALVE NUMBER
ACDC  1/4 NPT PORTS

3000*3000*1/32.022H23GG19DCM
2500*1500*3/64.041H23HH19DCMG
1750*5001/16.065H23JJ19DCMG
650*1003/32.100H23KK19DCMG
     
LIQUID PRESSURE RATINGSORIFICE SIZECV FACTORVALVE NUMBER
ACDC  1/4 NPT PORTS

3000*3000*1/32.022H23GG19DCM
1500*1500*3/64.041H23HH19DCML
1000*5001/16.065H23JJ19DCML
3001003/32.100H23KK19DCML

* FKM seals not recommended for pressure above 500 psi.

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (H23JJ19DCV 120/60) repair pack (KH23JJ AC)


Operating Conditions

Media
Air and other non-corrosive gasses, water and oil.
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
10,000 PSI
Leakage
Bubbletight (with polymer sealing pins)
Filtration
Down to 60 microns or less is recommended.

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.3 Watts DC — 9.5 Watts (Per Operator)
Coil Construction
Molded (Std.) and Potted Class F or Class H (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM with gas media
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Sealing Pin
Kel-F (Std.)
Orifice Diameter
See table above.
Porting
1/4" NPT
Mounting
Must be mounted within 30° of vertical.
Housing
Grommet or 1/2" NPT conduit
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
3.63 lbs
Repair Packs
See table above.
Options
Alternate Sealing Pin Materials and Alternate Elastomers*

Series 20 High Pressure Valves Conduit

MODEL H23 CONDUIT 3WNC HIGH PRESSURE

3WNC
HIGH PRESSURE
CONDUIT CONNECTION

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1