Series 70 Model N76


3-WAY MULTI-PURPOSE Valve


The 70 line PeterPaul Hazardous Location valves are UL listed and certified for non-incendive Hazardous Locations — Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Groups E, F and G; T3C temperature rating.

  • Largest direct acting non-piloted valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORCONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.1/4 NPT PORTS

2252251/161/16.09.09N76JJ9ZCP
1501503/323/32.22.22N76KK9ZCP
1001001/81/8.35.35N76NN9ZCP
75755/325/32.45.45N76OO9ZCP
60603/163/16.50.50N76PP9ZCP

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (N76KK9ZCP 120/60) repair pack (NK76KKX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (ON76KKDDCP 120/60)


Operating Conditions

Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.
Certification
North American

Series 70 HAZARDOUS LOCATION VALVES

MODEL N76 1/4-18 NPT 3WNC Conduit Connection

MODEL N76 1/4-18 NPT 3WNC CONDUIT CONNECTION

MODEL N76 1/4-18 NPT 3WNC Conduit with Bracket

MODEL N76 1/4-18 NPT 3WNC CONDUIT WITH BRACKET

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1