Series 50 ELW Model ELW52


2-WAY NORMALLY CLOSED Valve


A UL and CSA listed, low watt, miniature hazardous location valve with minimal space and energy requirements in volatile environments. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.

  • Smallest hazardous location solenoid valve.
  • Best ambient and high temperature ratings on the market.
  • NEMA 4 rating is standard with encapsulated coil.
  • High quality engineering.
MAX. OPER. 
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GASLIQUID   
ACDCACDCN.C.N.C. 

6002006002001/32.022ELW52G8DCCP
25080250803/64.055ELW52H8DCCP
15050150501/16.075ELW52J8DCCP
10025100255/64.134ELW52V8DCCP
852085203/32.156ELW52K8DCCP
50 50 1/8.230ELW52N8DCCP
15 15 5/32.292ELW52O8DCCP

Operating Conditions

Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts DC — 1.8 Watts
Coil Construction
Encapsulated Class F Coil with third wire ground
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Encapsulated with 1/2" NPT conduit
Listings
Valves are UL listed for Hazardous Locations — Class I, Div 1, Groups A, B, C, and D - Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G. "T" Rating as low as T5.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.60 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*

Series 50 ELW Encapsulated Low Watt Valves

Model ELW52 2WNC Explosion Proof 1/8 NPT

MODEL ELW52
2WNC
EXPLOSION PROOF

Model ELW52 2WNC Explosion Proof 10-32 Ports

MODEL ELW52 10-32 PORTS
2WNC
EXPLOSION PROOF

Model ELW52 2WNC Explosion Proof Body Option E

MODEL ELW52 BODY OPTION "E"
2WNC
EXPLOSION PROOF

Model ELW52 2WNC Explosion Proof Body Option O

MODEL ELW52 BODY OPTION "O"
2WNC
EXPLOSION PROOF

Model ELW52 2WNC Explosion Proof Body Option R

MODEL ELW52 BODY OPTION "R"
2WNC
EXPLOSION PROOF

Model ELW52 2WNC Explosion Proof Metered Body

MODEL ELW52 METERED BODY
2WNC
EXPLOSION PROOF

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1