Series 50 LLW Model LLW52


2-WAY NORMALLY CLOSED Valve


General purpose or safety valves for pneumatic applications. The versatility of these valves is increased to include the handling of hot air, refrigerants, and many other media by the use of different seals. Air and other gases are compatible with standard Buna seals.

  • General purpose valve with reduced power consumption.
  • Increased versatility.
  • For pneumatic applications.
  • Increased capability to handle hot air and other gases.
  • High quality engineering.
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
GAS  
DCN.C.N.C.GROMMET 1/8" NPTCONDUIT 1/8" NPT

1201/32.022LLW52G8DGMLLW52G8DCM

Operating Conditions

Media
Air and other gases only compatible with standard Buna seals.*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12, 24/DC
Nominal Power
DC — 0.65 Watts
Coil Construction
Non-molded Class A, Molded and potted Class F. (Class H option)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most Valvesare U.L. and CSA listed - consult factory.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers*

Series 50LLW Low Watt Valves Conduit Connection


2WNC
CONDUIT CONNECTION


10-32 PORTS
2WNC CONDUIT CONNECTION


BODY OPTION "E"
2WNC CONDUIT CONNECTION


BODY OPTION "O"
2WNC CONDUIT CONNECTION


BODY OPTION "R"
2WNC CONDUIT CONNECTION


METERED BODY
2WNC
CONDUIT CONNECTION

 

Series 50LLW Low Watt Valves Conduit/Bracket Connection


2WNC
CONDUIT/BRACKET CONNECTION


10-32 PORTS
2WNC
CONDUIT/BRACKET CONNECTION


BODY OPTION "E"
2WNC
CONDUIT/BRACKET CONNECTION


BODY OPTION "O"
2WNC
CONDUIT/BRACKET CONNECTION


BODY OPTION "R"
2WNC
CONDUIT/BRACKET CONNECTION


METERED BODY
2WNC
CONDUIT/BRACKET CONNECTION

 

Series 50LLW Low Watt Valves Grommet Connection


2WNC
GROMMET WITH LEADS


10-32 PORTS
GROMMET WITH LEADS


2WNC
BODY OPTION "E"
GROMMET WITH LEADS


2WNC
BODY OPTION "O"
GROMMET WITH LEADS


2WNC
BODY OPTION "R"
GROMMET WITH LEADS


METERED BODY
2WNC GROMMET WITH LEADS

 

Series 50LLW Low Watt Valves Grommet/Bracket Connection


2WNC
GROMMET/BRACKET WITH LEADS


10-32 PORTS
2WNC
GROMMET/BRACKET WITH LEADS


BODY OPTION "E"
2WNC
GROMMET/BRACKET WITH LEADS


BODY OPTION "O"
2WNC
GROMMET/BRACKET WITH LEADS


BODY OPTION "R"
2WNC
GROMMET/BRACKET WITH LEADS


METERED BODY
2WNC
GROMMET/BRACKET WITH LEADS

 

Series 50LLW Low Watt Valves Yoke Leads


2WNC
YOKE WITH LEADS


10-32 PORTS
2WNC
YOKE WITH LEADS


BODY OPTION "E"
2WNC
YOKE WITH LEADS


BODY OPTION "O"
2WNC
YOKE WITH LEADS


BODY OPTION "R"
2WNC
YOKE WITH LEADS


METERED BODY
2WNC
YOKE WITH LEADS

 

Series 50LLW Low Watt Valves Yoke Spade Terminals


2WNC
YOKE WITH SPADE TERMINALS


10-32 PORTS
2WNC
YOKE WITH SPADE TERMINALS


BODY OPTION "E"
2WNC
YOKE WITH SPADE TERMINALS


BODY OPTION "O"
2WNC
YOKE WITH SPADE TERMINALS


BODY OPTION "R"
2WNC
YOKE WITH SPADE TERMINALS


METERED BODY
2WNC
YOKE WITH SPADE TERMINALS

Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1