Series 20 Model EH21


2-WAY NORMALLY OPEN Valve


This valve uses the same kinetic energy impact mechanism as the EH22 but incorporates an internal rocker arm to reverse the action of the sealing pin. The kinetic energy of the plunger is applied to one end of the rocker arm when the coil is de-energized. This lifts the sealing pin, on the opposite end of the rocker arm, against the force of high pressure. A return spring acts directly on the pin, sealing the orifice when the coil is energized. For use on Air and other non-corrosive gasses, water and oil.

  • Precision stainless steel rocker arm.
  • Kel-F pin sealing element.
  • Orifice guides the sealing pin for near perfect alignment.
  • Simple construction...only three moving parts.
  • Explosion proof construction.
MAX. OPER.
PRESS. DIFF. LIQUID
ORIFICE SIZECV FACTOR  VALVE NUMBER 
CONDUIT HOUSING
 
AC/DC    LIQUID 1/8 NPT          

          
30001/32.024  EH21G7DCCM-∆          
15003/64.052  EH21H7DCCML-∆          
8501/16.095  EH21J7DCCML-∆          
3003/32.156  EH21K7DCCML-∆          

MAX. OPER.
PRESS. DIFF. GAS
ORIFICE SIZECV FACTOR  VALVE NUMBER
CONDUIT HOUSING
 
AC/DC    GAS 1/8 NPT

30001/32.024  EH21G7DCCM-∆
25003/64.052  EH21H7DCCMG-∆
13501/16.095  EH21J7DCCMG-∆
4503/32.156  EH21K7DCCMG-∆

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

* FKM seals not recommended for pressure above 500 psi

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (EH21JDDCCMG 120/60) repair pack (2KEH21J AC)


Operating Conditions

Media
Air and other non-corrosive gasses, water and oil.
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
10,000 PSI
Leakage
Bubble tight for standard valves.
Filtration
Down to 60 microns or less is recommended.

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.3 Watts DC — 9.5 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM with gas media
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Sealing Pin
Kel-F (Std.), Delrin®, PEEK
Orifice Diameter
See table above.
Porting
1/8" NPT
Mounting
Must be mounted within 30° of vertical.
Housing
Flame-Proof construction with 1/2″ NPT conduit
Listings
Valves are UL listed for use in the United States and Canada for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2, Groups A, B, C, D, E, F, and G.
Certification
North American IECEx/ATEX
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
2.38 lbs
Repair Packs
See table above.
Options
Alternate Sealing Pin Materials and Alternate Elastomers*

Series 20 High Pressure Valves


SERIES 20 MODEL EH21
EXPLOSION PROOF/HIGH PRESSURE
2WNO
 

 
Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1


GP-1119 ATEX IECEx UKEx Signed Declaration of Conformity page 1 GP-1119 ATEX IECEx UKEx Signed Declaration of Conformity page 2