2-WAY NORMALLY OPEN Valve
The N70 line PeterPaul Hazardous Location valves are UL listed and certified for non-incendive Hazardous Locations — Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Groups E, F and G; T3C temperature rating.
- Largest direct acting non-piloted valve we manufacture.
- Large orifice.
- High flow.
- Will operate effectively at very low pressures or vacuum.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | CONDUIT HOUSING | |
|---|---|---|---|---|
| AC | DC | 1/4 NPT PORTS | ||
| 350 | 350 | 1/16 | .09 | N71J9ZCP |
| 250 | 250 | 3/32 | .22 | N71K9ZCP |
| 175 | 175 | 1/8 | .35 | N71N9ZCP |
| 125 | 125 | 5/32 | .45 | N71O9ZCP |
| 100 | 100 | 3/16 | .50 | N71P9ZCP |
Ordering Information:
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (N71P9ZCP 120/60) repair pack (KN71PDX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (ON71PDDCP 120/60)
Operating Conditions
- Media
- Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
- Valve Temperature Range
- Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
- Maximum Operating Pressure Differentials
- See table above.
- Burst Pressure
- 4000 PSI
- Leakage
- Bubble tight for standard valves.
- Vacuum
- To 5 Microns*
Electrical Characteristics
- Coil Voltage
- 12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
- Nominal Power
- AC — 18.0 Watts DC — 16.0 Watts
- Coil Construction
- Potted Class F. (Class H optional)
- Typical Response Time on Air
- 4 - 16 Milliseconds
- Operating Speed
- Up to 600 CPM
- Duty Cycle
- Continuous
Mechanical Characteristics
- Internal Components
- Stainless Steel. Copper – AC Only.
- Elastomers
- Nitrile (Buna) (Std.). Many other elastomers available.*
- Orifice Diameter
- See table above.
- Porting
- Standard 1/4" NPT (other ports available).*
- Life Expectancy
- Millions of cycles, depending on application, lubrication, etc.
- Valve Weight
- Conduit Valve: 2.06 lb
- Repair Packs
- See table above.
- Options
- Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.
- Certification
- North American
Series 70 HAZARDOUS LOCATION VALVES

MODEL N71 1/4-18 NPT 3WNC CONDUIT CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com 
MODEL N71 1/4-18 NPT 3WNC CONDUIT WITH BRACKET

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.
The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.
Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.