Series 70 Model 75


3-WAY DIRECTIONAL CONTROL Valve


Super valves that have ratings that formerly required valves of much greater size. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Largest direct acting (non-piloted) valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
CONDUIT HOUSING
ACDCN.C.N.O.N.C.NO1/4 NPT PORTS1/4 NPT PORTS

3503501/161/16.09.0975JJ9ZGM75JJ9ZCM
2502503/323/32.22.2275KK9ZGM75KK9ZCM
1751751/81/8.35.3575NN9ZGM75NN9ZCM
1251255/325/32.45.4575OO9ZGM75OO9ZCM
1001003/163/16.50.5075PP9ZGM75PP9ZCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (75OO9ZGM 120/60) repair pack (K75OOX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O75OODDGM 120/60)


Operating Conditions

Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Molded Class F (Std.), Potted and Class H Option
Typical Response Time on Air
4 – 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 2.00 lb Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers

Series 70 3-WAY DIRECTION CONTROL DIN STYLE COIL

MODEL 75 
1/4-18 NPT 3-WAY DIRECTION CONTROL DIN STYLE COIL

 

Series 70 General Purpose Valves Conduit


MODEL 75 1/4-18 NPT
3-WAY DIRECTIONAL CONTROL
CONDUIT CONNECTION
 

 

Series 70 General Purpose Valves Grommet


MODEL 75 1/4-18 NPT
3-WAY DIRECTIONAL CONTROL
GROMMET WITH LEADS
 

 

Series 70 General Purpose Valves Grommet/Bracket Connection

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
MODEL 75 1/4-18 NPT
3-WAY DIRECTIONAL CONTROL
GROMMET/BRACKET CONNECTION
 

 

Series 70 General Purpose Valves Conduit/Bracket Connection

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
MODEL 75 1/4-18 NPT
3-WAY DIRECTIONAL CONTROL
CONDUIT/BRACKET CONNECTION
 

 
Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1