Series 50 LW Model LW53


3-WAY NORMALLY CLOSED (e to a) Valve


General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants, and many other media by the use of different seals. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.

  • General purpose valve with reduced power consumption.
  • Increased versatility.
  • For pneumatic and hydraulic applications.
  • Increased capability to handle hot air, water, and refrigerants.
  • High quality engineering.
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
GASLIQUID  
ACDCACDCN.C.N.O.N.C.N.O.GROMMET 1/8" NPTCONDUIT 1/8" NPT

2151352151351/321/32.022.022LW53GG8DGMLW53GG8DCM
215120120651/323/64.022.048LW53GH8DGMLW53GH8DCM
1355040301/321/16.022.075LW53GJ8DGMLW53GJ8DCM
703530201/325/64.022.134LW53GV8DGMLW53GV8DCM
553025151/323/32.022.156LW53GK8DGMLW53GK8DCM
12070120653/643/64.055.048LW53HH8DGMLW53GN8DCM
1205040303/641/16.055.075LW53HJ8DGMLW53GO8DCM
703530203/645/64.055.134LW53HV8DGMLW53HV8DCM
553025153/643/32.055.156LW53HK8DGMLW53HK8DCM
854040301/161/16.075.075LW53JJ8DGMLW53JJ8DCM
703530201/165/64.075.134LW53JV8DGMLW53JV8DCM
553025151/163/32.075.156LW53JK8DGMLW53JK8DCM
503030205/645/64.134.134LW53VV8DGMLW53VV8DCM
503025155/643/32.134.156LW53VK8DGMLW53VK8DCM
352025153/323/32.150.156LW53KK8DGMLW53KK8DCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. for examples: valve (LW53JJ8DGML120/60) repair pack (KLW53JJD AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OLW53JJDDGML 120/60)


Operating Conditions

Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Electrical Characteristics

Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 2.5 Watts DC — 2.5 Watts
Coil Construction
Non-molded Class A, Molded and potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous

Mechanical Characteristics

Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Grommet and 1/2" NPT conduit - many options available.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers*

Series 50 LW Low Watt Valves Conduit Connection


3WNC EXHAUST TO ATMOSPHERE
CONDUIT CONNECTION

 

Series 50 LW Low Watt Valves Grommet with Leads


3WNC EXHAUST TO ATMOSPHERE
GROMMET WITH LEADS

 

Series 50 LW Low Watt Valves Yoke With Leads


3WNC EXHAUST TO ATMOSPHERE
YOKE WITH LEADS

 

Series 50 LW Low Watt Valves Yoke With Spade Terminals


3WNC EXHAUST TO ATMOSPHERE
YOKE WITH SPADE TERMINALS

 
Nomenclature, all valve series except 58

PeterPaul has created this page for you so you can calculate the flow or Cv (flow coefficient) to make the relationship visible between the pressure drop (the difference in pressure between two points of a liquid/gas carrying network) and the flow rate.

The use of this flow coefficient (Cv) calculator offers a standard calculation to compare valve capacities and sizing for a wide range of applications. The type and sizing of a valve or regulator can have a large impact on the performance of the assembly for transferring gas or liquids in the system.

Our sales department is ready to answer questions and to solve your valve needs. Please feel free to call, chat or email us.

Liquid Flow

Calculate Flow in GPM


Calculate Cv


Calculate P1-P2


Gas Flow P2 > 53% of P1 subsonic

Calculate Flow in CFM


Calculate Cv


Approx. Calculate P1


Approx. Calculate P2


Gas Flow P2 < 53% of P1 sonic

Calculate Flow in CFM


Calculate Cv


Calculate P1